Imex Ct+ Obstetrical/Vascular Doppler - W/ 2 & 8 MHZ Probes - Discontinued
Details
The Imexdop Ct+ Obstetrical/Vascular Doppler - w/ 2&8 MHZ Probes
The IMEXDOP CT+ is a larger unit with dual speakers and a large, easy-to-read display. This unit's smart charging stand can be mounted to the wall, counter or IV pole. It is surprisingly lightweight, but large enough not to be lost or taken. Built-in dual speakers offer superb sound quality. Patient and others can hear fetal heart beat. One system can be used for both obstetrical and vascular applications due to the interchangeable probes.
Obstetrical applications include reassuring the mother, detecting pregnancy and determining multiple pregnancies. The 2 MHz probe is best for use in detecting fetal heart tones after 12 weeks and throughout labor and delivery. It can also be used on obese patients. The 2 MHz probe is good for hospital labor and delivery areas. The waterproof 2 MHz probe is for late pregnancy and underwater labor and delivery use. The 3 MHz probe is designed for increased sensitivity in the early stages of pregnancy. It can detect fetal heart tones as early as 8 to 10 weeks. When using only one probe, this is the best choice.
Vascular applications include helping to detect arterial disease and venous disease, assessing blood pressures, checking for impotence and locating vessels for IVs and any other application where detection and monitoring of blood flow is important. The 5 MHz probe is used for general vascular diagnosis. It may be used for deep arterial and venous flow detection. The 8 MHz probe is a vascular probe used for superficial vessel studies. It can be used to help assess blood pressures and detect blood flow in digits.
IMEXDOP CT+ Technical Specifications Dimensions:Dimensions: Weight: Power source: Battery type: Battery capacity: Battery recharge time: Display range: Display resolution: Display accuracy: | 4.3 x 6.2 x 8.8 inches (10.9 x 15.7 x 22.4 cm) 2.7 lb. (1.2 kg) 110V recharger (220V optional) 12V NiCad, user replaceable 75 minutes typical (away from charger) 14 hours Fetal: 60-210 beats per minute Vascular: 60-119 beats per minute 1 beat per minute +/-1 beat per minute at low end of display range; +/-5 beats per minute at high end of display range |
This product is discontinued.
This product has been discontinued. For information on a similar product or replacement please call us.
Discontinued | Yes |
---|---|
Unit of Measure (UOM) | Each |
Choose your Option 1 | w/ 2&8 MHZ Probes |
Style | with 2&8 MHZ Probes |